Assessment of Medical X-Ray Radiographic Screen-Films in Different Spatial Frequencies According To Detective Quantum Efficiency Computation
DOI:
https://doi.org/10.14331/ijfps.2012.330026Keywords:
Detective Quantum Efficiency (DQE), Diagnostic Radiology, Image quality, Screen-filmAbstract
In medical imaging, to make better images there are some measures such as detective quantum efficiency (DQE) and noise equivalent quanta (NEQ) used to evaluate the image quality of each imaging system. Detective quantum efficiency (DQE) is one of the important measures in the assessment of image quality and detector performance. DQE of two types of screen-films namely Lanex Regular/T-Mat G/RA and Lanex Regular/T-Mat L/RA were determined using MTF and NPS data, separately. Moreover, gamma was calculated from characteristic curves for each screen film and photon flounce was estimated using published literature. DQE of the screen-films were computed for three optical densities 0.7, 1.0 and 1.4. The results show Lanex Regular/T-Mat G has better DQE than Lanex Regular/T-Mat L -especially at low frequency with higher contrast for diagnostic radiology purposes.
Downloads
References
Beutel, J. (2000). Handbook of medical imaging: Physics and psychophysics (Vol. 1): Spie Press.
Bushberg, J. T. (2002). The essential physics of medical imaging: Williams & Wilkins.
Commission, I. E. (2007). Medical electrical equipment: characteristics of digital x-ray imaging devices—part 1: determination of the detective quantum efficiency. IEC Report(62220-1).
Curry, T. S., Dowdey, J. E., Murry, R. C., & Christensen, E. E. (1990). Christensen's physics of diagnostic radiology: Lippincott Williams & Wilkins.
Dainty, J., & Shaw, R. (1974). Image Science, Ch. 7: Academic Press, London.
Doi, K. (2006). Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology. Physics in Medicine and Biology, 51(13), 5.
Hassan, W., Saridan, W. M., Munajat, Y., & Sahibuddin, S. (2004). Determination of noise equivalent quanta of medical screen-films. Jurnal Teknologi(40C), 11-19.
Hendee, W. R., & Ritenour, E. R. (2002). Medical imaging physics: John Wiley and Sons.
Hubbell, J., & Seltzer, S. (1996). Tables of X-ray mass attenuation coefficients. National Institute of Standards and Technology NISTIR, 5632.
Johns, H. E. (1983). The physics of radiology. Khanmirzaei, M. H., Hassan, W. M. S. W., 2012. Computation of Detective Quantum Efficiency, Lap Lambert Academic Publishing, Germany.
Lemoigne, Y., Caner, A., & Rahal, G. (2007). Physics for medical imaging applications (Vol. 240): Springer Verlag.
Martin, C., Sharp, P., & Sutton, D. (1999). Measurement of image quality in diagnostic radiology. Applied radiation and isotopes, 50(1), 21-38.
Metz, C. E., Wagner, R. F., Doi, K., Brown, D. G., Nishikawa, R. M., & Myers, K. J. (1995). Toward consensus on quantitative assessment of medical imaging systems. Medical physics, 22, 1057.
Monnin, P., Gutierrez, D., Bulling, S., Lepori, D., & Verdun, F. (2005). A comparison of the imaging characteristics of the new Kodak Hyper Speed G film with the current T-MAT G/RA film and the CR 9000 system. Physics in Medicine and Biology, 50, 4541.
Prince, J. L., & Links, J. M. (2006). Medical imaging signals and systems: Pearson Prentice Hall.
Published
Issue
Section
License
Copyright (c) 2012 International Journal of Fundamental Physical Sciences

This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.
WorldCat
Scilit
ORCID